– Process temperature. Selected as input to AIFB by setting 'Channel' = 4. Unit derives from

'Temperature.unit'

temperature_unit

– Unit code of 'Temperature', 'Max/Min_peak_temperature_value'

– °C, °F, K, °R

max_peak_temperature_value

– Holds the maximum process temperature. Write access resets to current value. Unit derives

from 'Temperature.unit'

– Write access resets to current value

min_peak_temperature_value

– Holds the minimum process temperature. Write access resets to current value. Unit derives

from 'Temperature.unit'

– Write access resets to current value

10.3 Dimensioni

I seguenti disegni quotati illustrano solo alcune delle possibili esecuzioni. Disegni quotati dettagliati

possono essere scaricati dal sito www.vega.com sotto "Downloads" e "Disegni".
Le custodie a due camere non sono disponibili per apparecchi con uscita del segnale 4 … 20 mA

Custodia in resina

~ 69 mm

(2.72")

ø 79 mm

(3.03")

112 mm (4.41"

)

M20x1,5/

½ NPT

~ 84 mm (3.31")

M16x1,5

112 mm (4.41"

)

M20x1,5/

½ NPT

1

2

ø 79 mm

(3.31")

Figura 30: Le differenti custodie con grado di protezione IP 66/IP 68 (0,2 bar) - con tastierino di taratura con

display incorporato l'altezza della custodia aumenta di 9 mm/0.35 in
1 Esecuzione a una camera

2 Esecuzione a due camere