INSTALLATION - GAS CONNECTION

The following technical instructions are intended for installers.

The cooker is thermally insulated (according to EN standards) and can be fitted next to

furniture which must no be higher than the hob (Type X).

The 60 X 60 cooker can be fitted next to other furniture if the latter are made of materials

capable of withstanding a temperature of 100°C.

This appliance is not connected to an exhaust flue. It must be installed in accordance with

the regulations in force in the country of use. Care must be taken to follow the regulations

regarding ventilation. The airflow necessary to the combustion must be 2 m

3

/h by kW of

power.

GAS CONNECTION - It must be carried out in accordance with the regulations in force

in the country of use. However, in all circumstances the gas supply pipe should be

fitted with a stop tap, a pressure regulator or a pressure reducer release valve for LPG. The

stop tap, pressure regulator or pressure reducer release valve should only be used in

accordance with the regulations in force in the country of use.

Built-in appliances :

Butane gas

Rigid hose - Flexible hose with mechanical nozzles (2) - Flexible rubber

pipe (1)

Propane gas

Rigid hose - Flexible hose with mechanical nozzles (2)

Natural gas

Rigid hose - Flexible hose with mechanical nozzles (2)

Free-standing appliances :

Butane gas

Rigid hose - Flexible hose with mechanical nozzles (2) - Flexible rubber

pipe (1)

Propane gas

Rigid hose - Flexible hose with mechanical nozzles (2) - Flexible rubber

pipe (1) (3)

Natural gas

Rigid hose - Flexible hose with mechanical nozzles (2) - Flexible rubber

pipe (3)

(1) with the proviso that the flexible pipe should be located so that it can always be inspected

along the whole of its length. It should not exceed 1.5 metres in length and should be fitted

with sealing joints ate each end.

(2) with the proviso that the flexible hose should be located so that it can always be inspected

along the whole of its length.

(1) (2) Both the flexible pipes and the flexible hoses with mechanical nozzles should be

located so that they cannot come into contact with a naked flame, nor suffer damage from

the combustion gases, the hot parts of the appliance or from the spillage or hot liquids.

(3) Reserved exclusively for old installations which do not offer any alternative for

connection.