English, Factors affecting readings, Technical data – SOEHNLE 7850 Manuale d'uso

Pagina 4

Advertising
background image

ENGLISH

Fitness Scale 7850

4

Factors affecting readings

The analysis is based on a measurement of the
electrical body resistance. Eating and drinking
habits during the day and private lifestyles influence
the body’s fluid balance.
This is noticeable by fluctuations in the readings.
To obtain analysis results that are highly precise and
iterative, make sure that the measurement conditions
are constant. Only then will you be able to observe
changes precisely over a long period of time.

In addition, other factors may affect fluid
balance:

After a bath the indicator will display a body
fat percentage that is too low and a body water
percentage that is too high

After a meal the indicator may be higher

Women are subject to fluctuations due to their
menstrual cycle

Body fluids are lost due to illness or after bodily
exertion (sport) After sporting activity, you
should wait for a period of 6 to 8 hours before
taking the next measurement

Anomalous or implausible readings may occur
in the following situations:

Persons with fever, oedema symptoms or
osteoporosis

Persons undergoing dialysis therapy

Persons taking cardiovascular medication

Pregnant women

Athletes who do more than 10 hours of intensive
training a week and have a resting heart rate
under 60 bpm

Competitive athletes and body builders

Young people under 17 years old

Technical data

Weighing range:

180 kg

Division:

100 g

Operating temperature: 15°C bis 35°C
Max. air humidity:

85 %

Storage temperature:

–30° bis 70°C

Power supply:

power adapter input
220VAC, output 6VDC,
protection class IP 54

Battery:

Lithium battery CR2032,
3V for the power supply
of time and date settings

Printer:

thermal printer, paper
width 58 mm

Print paper:

thermal paper outside layer,
49,5 mm wide, max. roll di-
ameter 50mm, commercially
available, Order Number
from Soehnle Professional
2500.01.008
(pack containing 10 rolls)

Advertising