Care instructions, Dismantling, Storage – Gardena WP 1500 S Manuale d'uso

Pagina 5: Information

Advertising
background image

1

2

3

4

5

6

15

G

14

G

Cleaning the filter tank

Blocked feed impeller

Avoid dry operation of the pump as dry running will produce
undesirable heat and destroy the pump.

.

Loosen the regulator by turning it anti-clockwise until you

achieve the desired water flow from the vertical pipe of the
fountain / water feature.

.

You may connect other terminals to the second outlet.

For example, a separately installed water jet may be operated
via the GARDENA Fountain / Light Bracket, Art. No. 7886.
If necessary fix the bracket with two screws.

Information:
This significantly reduces the volume of the vertical water jet.

.

If the max. delivery capacity of the second outlet is to be used

then the vertical outlet should be closed with the end cap sup-
plied.

.

Example: Hose pipe connection with the GARDENA

Fountain / Light Bracket
We recommend the use of a 3 /4” (19 mm) GARDENA Pond
Hose Pipe, Art. No. 7895, connected to with the GARDENA
“Profi” Maxi-Flow-System with Tap Connector (Art. No. 2801
and 2802) and the GARDENA “Profi” Maxi-Flow-System Hose
Connectors (Art. No. 2817).

Care Instructions

Filter tank and pump should be free from dirt particles!

How to clean :

.

Disconnect the plug from the solar panel !

.

Remove the pump from the water.

.

If necessary remove the gravel.

.

Clean the pump and the filter using a water jet.

.

If there are deposits of dirt inside the pump then dismantle the

casing (

➔ see “Dismantling”) and carefully clean the interior

fittings with water.

Information: Do not use any hard objects or strong detergents!

If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).

Avoid dry operation

Horizontal or
second outlet

Complaints / Repairs

Product liability

Dismantling

1.

Disconnect the plug from the solar panel !

2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically upwards out of the filter tank.

5. Pull the suction filter casing

1

for-

wards and remove it.

6. Remove the foam filter

2

from the

suction piece of the pump.

7. Turn the pump casing

3

to the left

to the limit stop and then
pull it straight towards the front and
remove it! Do not tilt!

8. Pull the feed impeller

4

out of the

motor casing

6

.

.

Then assemble all the fittings reversing the order and direction

in which they were dismantled. Please take care that the seal
ring

5

is properly re-fitted.

➔ Make sure while assembling that you attach the pump casing

with the pressure joint being cated, press it firmly and then
turn it straight to the right.

➔ Observe the markings.

Storage

A

The pump should be stored out of the reach of children.

1. Remove the pump from the pond and store away from frost

before the first frost sets in.

2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.

The mains plug must not be submerged.

Information

If you have any problems with your Fountain Pump, please con-
tact our Service or return the defective unit together with a short
description of the problem – in case of guarantee, with the
warranty card duly completed and signed – postage paid to one
of the GARDENA Service Centres listed on the back of this leaflet.

We expressly point out that, in accordance with the product
liability law, we are not liable for any damage caused by our
units if it is due to improper repair or if parts exchanged are not
original GARDENA parts or parts approved by us, and, if the
repairs were not carried out by a GARDENA Service Centre or
an authorised specialist. The same applies to spare parts and
accessories.

Where to store

Advertising
Questo manuale è associato alle seguenti prodotti: