MAIN GUIDELINES

-

Do not mount the luminaire near a flammable surface.

-

Use the luminaire in dry locations only, where humidity does not exceed 90 percent.

-

The luminaire is for indoor use only and is not intended for outdoor use.

-

For temporary installations, mount and support the luminaire only by the primary suspension
yoke holes. Suspend the luminaire from a hook clamp (PLH295-PLH300 optional).

-

In addition to primary suspension, use a steel safety cable (PLH200 optional) to the secondary
suspension point.

-

If the external cable is damaged, it shall be replaced by our service agents.

-

Always hang the luminaire with the colour frame held securely behind the retaining clip.

-

Always replace the lamp if it becomes damaged or thermally deformed.

-

Disconnect the unit from power before all cleaning and maintenance.

-

The luminaire is suitable for indoor use with a maximum ambient temperature: Ta=45°C

-

Maximum exterior surface temperature: T

max

: 250°C.

-

Keep the luminaire at least 2.5 meters away from any lit surface.

LUMINAIRE

INFORMATION


A plug of at least 2.5 amp (220/240V) rating should be attached to the luminaire’s mains lead. The
wires in the mains lead are 1.55mm2 each and coloured in accordance with the following code:

GREEN/YELLOW: Ground
BLUE:

Neutral

BROWN:

Live


WARNING: the luminaire must be earthed

Current rating:

5A max./120V

2,5A

max./230V


Operating frequency:

50/60Hz


Lamp type:

HPL 575/750W