Troubleshooting

Problem

Possible cause

Solution

The instrument does

not turn on.

No power is supplied.

Defective power

cable. Fuse is blown

inside the instrument

Please make sure that

power is available and

switched on. Check

the power cable and

the internal fuse and

replace if needed, with

fuse as specified .

The instrument does

not send MIDI data.

MIDI Module is swit-

ched off.

Switch MIDI Module

on by pressing On/Off.

The instrument can not

be controlled via MIDI.

MIDI data are not

sent on MIDI channel

1 or 2

Please send MIDI data

only on MIDI channel 1

and/or 2

The instrument just

plays / sends a fixed

velocity value

Fixed Velocity is

selected.

Select a different velo-

city curve.

No sound is heard.

Sound Bank is

switched off.

Volume is set to 0.

Defective connecting

cable / headphone.

A sustain pedal is

connected to Expres-

sion pedal input.

Switch Sound Bank on

by pressing On/Off.

Set the Volume to a

higher level.

Change the cable /

headphone.

Unplug the sustain

pedal from expression

pedal in.

Only one sound is

heard in split or layer

mode.

Balance knob is set

to either Upper or

Lower.

Change the Balance

value.

No sound from the

audio input is heard.

Level of Audio In is

set to minimum.

External sound de-

vice is not playing.

Defective cable con-

nection.

Adjust Level.

Check if the external

sound device sends

audio signal. Change

the connection cable.

Sustain pedal holds

notes if it is not pressed,

but cuts notes if

pressed.

A non suitable pedal

is connected and/or

the instrument has

not recognized the

pedal‘s polarity

Use the proper Pedal

and/or turn the instru-

ment off and on again,

without pressing the

pedal, to allow the in-

strument to recognize

the pedal‘s polarity

Adjustments (eg of

effect Amount or effect

Mix) are not sent by the

instrument or cannot

be recorded with a

sequencer software.

The instrtument is

not set to MIDI chan-

nel 16.

The MIDI Input of the

sequencer is not set

either to channel 16

or to “all inputs”.

Set MIDI Module to

MIDI channel 16 and

switch it on.

Set the input of the

sequencer to MIDI

channel 16 or to “all

inputs”.

Other MIDI sound

modules do not

automatically tune

themselves to the inter-

nal instrment‘s tuning.

The external sound

module ignores MIDI

SysEx messages.

The MIDI channels

are not identical.

Enable the sound

module to receive and

process MIDI SysEx

messages.

Set the instrument and

the external sound

module to the same

MIDI channel.