Rr tc s s a, Burner and nozzle specifications – Hotpoint Ariston PFS 750 T (IX)-HA Manuale d'uso

Pagina 15

Advertising
background image

GB

15

Burner and nozzle specifications

Table 1 Liquid Gas Natural Gas

Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*

power power 1/100 1/100 (g/h) power 1/100 (l/h)

kW kW kW

(p.c.s.*) (p.c.s.*) (p.c.s.*)

(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Reduced Fast (RR) 100 0,70 2,60 39 80 189 186 2,60 110 (Y) 248
Semi Fast (S) 75 0,40 1,90 28 70 138 136 1,90 106 181
Auxiliary (A) 55 0,40 1,00 28 50 73 71 1,00 79 95
Triple Crown (TC) 130 1,50 3,30 61 91 240 236 3,60 145 (H1) 343

Supply Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20

35

37

25

45

20

17

25

*

At 15°C and 1013 mbar - dry gas

**

Propane

P.C.S. = 50.37 MJ/Kg

***

Butane

P.C.S. = 49.47 MJ/Kg

Natural

P.C.S. = 37.78 MJ/m

3

PFS750T/HA

EHP 750 T /HA

RR

TC

S

S

A

! The hob can only be installed above built-in ovens with a cooling ventilation system.

Advertising