VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol Approval according to LPR radio standard Manuale d'uso

Pagina 83

Advertising
background image

o;

P

arametri

L

ength

C

ode/Data

Assign Unit Number

6 characters ASCII

UuuNOK
uu = new Address

S

et number of Floats

R

equest:

P

arametri

L

ength

C

ode/Data

Set number of Floats

5 characters ASCII

UuuFn

R

esponse:

P

arametri

L

ength

C

ode/Data

Set number of Floats

6 characters ASCII

UuuFOK

Se il numero viene impostato su 0, non viene più segnalato alcun livello

S

et Baud Rate

R

equest:

P

arametri

L

ength

C

ode/Data

Set Baud Rate

8 (12) characters ASCII

UuuBbbbb[b][pds]
Bbbbb[b] = 1200, 9600 (default)
pds = parity, data length, stop bit
(optional)
parity: none = 81, even = 71 (de-
fault), odd = 71

R

esponse:

P

arametri

L

ength

C

ode/Data

Set Baud Rate

11 characters ASCII

Esempio: U01B9600E71

Modificare l'apparecchio all'indirizzo 1 impostando il baud rate 9600, parità pari, 7 bit di dati, 1 bit di
stop

S

et Receive to Transmit Delay

R

equest:

VEGAPULS 61 • Omologazione secondo la direttiva radio LPR (Level Probing Radar)

83

11 Accessori

41717

-IT

-120817